UL Approved 1-10V Microwave Sensor 3-6m Mounting Height For Corridor Function

Place of Origin Shenzhen, China
Brand Name Merrytek
Certification UL
Model Number MC612V D 99
Minimum Order Quantity 100pcs
Price Negotiable
Packaging Details Clapboard + Carton(K=A)
Delivery Time Clapboard + Carton(K=A)
Payment Terms T/T

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Rated Voltage 120/277VAC 50/60Hz Stand-by Power ≤1W
Output Dimming Mode 0-10VDC Dimming Signal/ ON/OFF Signal Mounting Height 3-6m (ceiling Mounting)
IP Rating IP20 Installation Built-in
Operating Temperature -35~70℃ Lifetime 5 Years Warranty @Ta 230V
High Light

Microwave Sensor For Corridor

,

1-10V Microwave Sensor

,

UL Approved Microwave Sensor

Leave a Message
Product Description

UL Approved 1-10V microwave sensor for corridor function
 
 
【Product Feature】

  • Patented Coupled Pole Antenna
  • With mini sensor detector, which does not block light
  • Low transmitting power, no harm to human
  • Support Remote Controller and DIP switch to adjust parameters
  • low side lobe; better adaptability to metal warehouse; Strong anti-interference ability
  • With Sync port for wiring grouping
  • 0-10V match MS01 can achieve daylight harvesting function
  • Not affected by temperature, humidity, noise, dust etc.

 
【Function】
 

√ON-OFF function ○Daylight harvesting
√2-step dimming ○Daylight priority
√3-step dimming ○High-low sensitivity
○override function √Grouping

 

 

【Product Information】

 

  • Dimension (Unit:mm)

UL Approved 1-10V Microwave Sensor 3-6m Mounting Height For Corridor Function 0

 

  • Wiring, Function

UL Approved 1-10V Microwave Sensor 3-6m Mounting Height For Corridor Function 1UL Approved 1-10V Microwave Sensor 3-6m Mounting Height For Corridor Function 2

 

Installation Instruction

 


UL Approved 1-10V Microwave Sensor 3-6m Mounting Height For Corridor Function 3
 

Note

The sensor is allowed to be connected to one load only. The sensor may be damaged if connecting more than one load.
Sensor antenna should be above LED tray.

 
DIP Setting

 

 

UL Approved 1-10V Microwave Sensor 3-6m Mounting Height For Corridor Function 4

 

【Detection Range】

 


UL Approved 1-10V Microwave Sensor 3-6m Mounting Height For Corridor Function 5


 【Parameter】

 

 

Input
Rated Voltage 120/277VAC 50/60Hz
Stand-by Power ≤1W
Surge Test 1KV(L/N,EN61000-4-5)
Output
Output dimming Mode 0-10VDC Dimming Signal ON/OFF Signal
Load Capacity @120VAC 3.6A Ballast @277VAC 3.4A Ballast
Max. Surge Capacity 30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start)
Dim interface
0-10V Dimming

< 50mA(Non-constant source)
10%(1-2V) 20%(1.9-2.1V) 30%(2.9-3.1V) 40% (3.9-4.1V)

Sensor Parameter
Operating Frequency 5.8 GHz ±75MHz, ISM wave band.
Transmitting power 1mW Max.
Detecting Radius

1m/s ≥2.5m. @ 3m ceiling mounting, 1m/s ≥4m @ 2m wall mounting
Test conditions : the product is set to 100% sensitivity, and there is no obvious occlusion in the room of 60㎡, 165cm person.

Mounting Height 3-6m (ceiling mounting)
3db beam angle 80°@XZ plane
96°@YZ plane
Environment
Operating Temperature -35~70℃
Storage Temperature -40℃~80℃, Humidity: ≤85%(Non-condensing)
Certificate Standard
Certificate UL
Environmental Requirement Compliant to RoHS 2.0, Reach
Safety Standards UL60730
IP Rating IP20
Protection Class Class II
Other
Wiring Press-in terminals wire diameter:10-24 AGW
Installation Built-in
Package Clapboard + Carton(K=A)
Net Weight 99.7±3g
Lifetime 5 years warranty @Ta 230V

 
 
Remote


UL Approved 1-10V Microwave Sensor 3-6m Mounting Height For Corridor Function 6
 
 

【Initialization】

  • Switch function/three-stage dimming function: the light will be turned on 100% brightness by the initial energizing sensor, and will be turned off after 10 seconds. During initialization, no external motion sensing signal will be detected.
  • Two-phase dimming function: the light will turn on 100% brightness in the initial energizing sensor, and turn to low brightness 10 seconds later (the brightness set by stand-by dim level). During initialization, no external motion sensing signal will be detected.

 
【Default setting】

 

Sensitivity: 100%, Hold time: 5s, Daylight sensor: Disable, Stand by period: 0s, Stand by DIM level: 50%
 
【Application Notice】

  • Sensor should be installed by a professional electrician. Please turn off power before installing, wiring, or setting the DIP switches.
  • Microwaves cannot penetrate metal. Do not place product in a closed or a half-closed metal lamp. Neither metal nor glass is not allowed to cover above the product. If antenna needs to pass through the metal plate, please ensure that the top of sensor is close to the metal plate.
  • Sensitivity area is related to moving speed of objects, size of moving objects, mounting height, mounting angle, working environment, reflecting materials and etc.. Given detecting area is typical value that was measured by 165cm high testers in an indoor open environment.
  • The daylight thresholds are measured on a sunny day without shadow and in an ambient light diffuse reflection status. Different environment and climate cause different brightness values that daylight sensor measures.
  • The installation spacing between sensors is recommended to be greater than 3m, and the installation spacing between sensors and routers is recommended to be greater than 2m.
  • Sensor should not be covered or hided by metal, PCB, LED tray etc..The spacing between the sensor antenna and surrounding materials should be greater than 5mm. There should be no metal or PCB tracks near the sensor antenna, above or below it. The recommended thickness of cover is 2mm, and keep the spacing between the sensor antenna and cover is greater than 3.2mm.
  • Vibration signals will be regarded as moving signals to trigger sensor. Installing sensor should be away from the object that vibrates for a long time, such as large metal equipment, pipes, air conditioning outlets, exhaust vents, smoke exhaust machine ports, shaking fans, etc. Pets in detecting area may cause false trigger.
  • The antenna surface of microwave module should be away from input AC, output DC, rectifier bridge, transformer, switch tube and other high-power devices to avoid high frequency signals affecting the normal operation of microwave sensor’s antenna.
  • Sensor is for indoor use only. The waterproof effect for outdoor or half-outdoor use will be affected. Wind, rain, and moving objects may cause false triggering.